Стр. 13
Страницы: | Стр.1 | Стр.2 | Стр.3 | Стр.4 | Стр.5 | Стр.6 | Стр.7 | Стр.8 | Стр.9 | Стр.10 | Стр.11 | Стр.12 | Стр.13 | Стр.14 | Стр.15 | Стр.16 | Стр.17 | Стр.18 | Стр.19 |
¦ ¦ (75)¦(133)¦(231)¦(353)¦(453)¦ (62)¦(116)¦(217)¦(342)¦(449)¦
+--------+-----+-----+-----+-----+-----+-----+-----+-----+-----+-----+
¦ 529 ¦ 95 ¦ 166 ¦ 293 ¦ 442 ¦ 566 ¦ 79 ¦ 145 ¦ 276 ¦ 428 ¦ 562 ¦
¦ ¦ (82)¦(143)¦(252)¦(380)¦(487)¦ (68)¦(125)¦(237)¦(368)¦(483)¦
+--------+-----+-----+-----+-----+-----+-----+-----+-----+-----+-----+
¦ 630 ¦ 109 ¦ 190 ¦ 330 ¦ 486 ¦ 624 ¦ 91 ¦ 165 ¦ 311 ¦ 471 ¦ 619 ¦
¦ ¦ (94)¦(163)¦(284)¦(418)¦(537)¦ (78)¦(142)¦(267)¦(405)¦(532)¦
+--------+-----+-----+-----+-----+-----+-----+-----+-----+-----+-----+
¦ 720 ¦ 120 ¦ 211 ¦ 363 ¦ 535 ¦ 688 ¦ 100 ¦ 183 ¦ 341 ¦ 519 ¦ 683 ¦
¦ ¦(103)¦(181)¦(312)¦(460)¦(592)¦ (86)¦(157)¦(293)¦(446)¦(587)¦
+--------+-----+-----+-----+-----+-----+-----+-----+-----+-----+-----+
¦ 820 ¦ 134 ¦ 231 ¦ 401 ¦ 605 ¦ 775 ¦ 110 ¦ 201 ¦ 377 ¦ 585 ¦ 766 ¦
¦ ¦(115)¦(199)¦(345)¦(520)¦(666)¦ (95)¦(173)¦(324)¦(503)¦(659)¦
+--------+-----+-----+-----+-----+-----+-----+-----+-----+-----+-----+
¦ 920 ¦ 148 ¦ 258 ¦ 438 ¦ 652 ¦ 825 ¦ 122 ¦ 224 ¦ 411 ¦ 632 ¦ 816 ¦
¦ ¦(127)¦(222)¦(377)¦(561)¦(709)¦(105)¦(193)¦(353)¦(543)¦(702)¦
+--------+-----+-----+-----+-----+-----+-----+-----+-----+-----+-----+
¦ 1020 ¦ 160 ¦ 279 ¦ 470 ¦ 692 ¦ 904 ¦ 133 ¦ 243 ¦ 440 ¦ 670 ¦ 896 ¦
¦ ¦(138)¦(240)¦(404)¦(595)¦(777)¦(114)¦(209)¦(378)¦(576)¦(770)¦
¦--------+-----+-----+-----+-----+-----+-----+-----+-----+-----+------
Примечание. Нормы удельных тепловых потерь определены из приложений 4, 5 документа "Типовые конструкции тепловой изоляции. Серия 3.903-9. Изоляция для трубопроводов надземной и подземной канальной прокладки водяных тепловых сетей, паропроводов и конденсатопроводов", утв. и введенного в действие Минмонтажспецстроем СССР 1 сентября 1977 г., издан ВНИПИ Теплопроект, Москва, 1977 г.
Приложение П
(обязательное)
Таблица П.1 - НОРМЫ ПЛОТНОСТИ ТЕПЛОВОГО ПОТОКА
ПРИ РАСПОЛОЖЕНИИ В ПОМЕЩЕНИИ (ТЕХНИЧЕСКОМ ПОДПОЛЬЕ)
И ТОННЕЛЕ (ПРОХОДНОМ КАНАЛЕ) ДЛЯ ТЕПЛОПРОВОДОВ СО СРОКОМ
ВВОДА В ЭКСПЛУАТАЦИЮ С 1994 Г. С ЧИСЛОМ ЧАСОВ РАБОТЫ
В ГОД БОЛЕЕ 5000
---------+------------------------------------------------------------¬
¦Наружный¦ Удельная плотность теплового потока, q , Вт/м (ккал/м·ч) ¦
¦диаметр,¦ н ¦
¦ d, мм +------------------------------------------------------------+
¦ ¦ Средняя разность температур теплоносителя и окружающего ¦
¦ ¦ трубопровод воздуха (помещение Дt = t - 15 / тоннель ¦
¦ ¦ пом ¦
¦ ¦ ¦
¦ ¦ Дt = t - 40, град. C) ¦
¦ ¦ т ¦
¦ +-----+------+-------+-------+-------+-------+-------+-------+
¦ ¦35/10¦ 85/60¦135/110¦185/160¦235/210¦285/260¦335/310¦385/360¦
+--------+-----+------+-------+-------+-------+-------+-------+-------+
¦ 21,3¦ 8 ¦ 18 ¦ 28 ¦ 40 ¦ 53 ¦ 66 ¦ 81 ¦ 96 ¦
¦ ¦(6,9)¦(15,5)¦ (24)¦ (34)¦ (45,6)¦ (57)¦ (70)¦ (82,6)¦
+--------+-----+------+-------+-------+-------+-------+-------+-------+
¦ 26,8¦ 9 ¦ 20 ¦ 32 ¦ 45 ¦ 58 ¦ 73 ¦ 89 ¦ 106 ¦
¦ ¦(7,7)¦ (17)¦ (27,5)¦ (39)¦ (50)¦ (63)¦ (76,5)¦ (91)¦
+--------+-----+------+-------+-------+-------+-------+-------+-------+
¦ 32 ¦ 10 ¦ 22 ¦ 35 ¦ 49 ¦ 64 ¦ 79 ¦ 97 ¦ 115 ¦
¦ ¦(8,6)¦ (19)¦ (30)¦ (42)¦ (55)¦ (68)¦ (83)¦ (99)¦
+--------+-----+------+-------+-------+-------+-------+-------+-------+
¦ 48 ¦ 12 ¦ 26 ¦ 41 ¦ 57 ¦ 74 ¦ 93 ¦ 112 ¦ 134 ¦
¦ ¦ (10)¦ (22)¦ (35)¦ (49)¦ (64)¦ (80)¦ (96)¦ (115)¦
+--------+-----+------+-------+-------+-------+-------+-------+-------+
¦ 57 ¦ 13 ¦ 28 ¦ 44 ¦ 61 ¦ 80 ¦ 99 ¦ 120 ¦ 142 ¦
¦ ¦ (11)¦ (24)¦ (38)¦ (52)¦ (69)¦ (85)¦ (103)¦ (122)¦
+--------+-----+------+-------+-------+-------+-------+-------+-------+
¦ 76 ¦ 15 ¦ 32 ¦ 50 ¦ 69 ¦ 90 ¦ 112 ¦ 134 ¦ 159 ¦
¦ ¦ (13)¦ (28)¦ (43)¦ (59)¦ (77)¦ (96)¦ (115)¦ (137)¦
+--------+-----+------+-------+-------+-------+-------+-------+-------+
¦ 89 ¦ 16 ¦ 35 ¦ 54 ¦ 74 ¦ 97 ¦ 119 ¦ 143 ¦ 169 ¦
¦ ¦ (14)¦ (30)¦ (46)¦ (64)¦ (83)¦ (102)¦ (123)¦ (145)¦
+--------+-----+------+-------+-------+-------+-------+-------+-------+
¦ 108 ¦ 18 ¦ 39 ¦ 60 ¦ 81 ¦ 105 ¦ 130 ¦ 156 ¦ 184 ¦
¦ ¦ (15)¦ (34)¦ (52)¦ (70)¦ (90)¦ (112)¦ (134)¦ (158)¦
+--------+-----+------+-------+-------+-------+-------+-------+-------+
¦ 133 ¦ 21 ¦ 44 ¦ 66 ¦ 90 ¦ 118 ¦ 145 ¦ 175 ¦ 205 ¦
¦ ¦ (18)¦ (38)¦ (57)¦ (77)¦ (101)¦ (125)¦ (151)¦ (176)¦
+--------+-----+------+-------+-------+-------+-------+-------+-------+
¦ 159 ¦ 24 ¦ 49 ¦ 73 ¦ 98 ¦ 130 ¦ 160 ¦ 190 ¦ 223 ¦
¦ ¦ (21)¦ (42)¦ (63)¦ (84)¦ (112)¦ (138)¦ (163)¦ (192)¦
+--------+-----+------+-------+-------+-------+-------+-------+-------+
¦ 219 ¦ 29 ¦ 59 ¦ 88 ¦ 118 ¦ 155 ¦ 189 ¦ 225 ¦ 261 ¦
¦ ¦ (25)¦ (51)¦ (76)¦ (101)¦ (133)¦ (163)¦ (194)¦ (224)¦
+--------+-----+------+-------+-------+-------+-------+-------+-------+
¦ 273 ¦ 34 ¦ 68 ¦ 100 ¦ 133 ¦ 174 ¦ 211 ¦ 249 ¦ 289 ¦
¦ ¦ (29)¦ (58)¦ (86)¦ (114)¦ (150)¦ (181)¦ (214)¦ (249)¦
+--------+-----+------+-------+-------+-------+-------+-------+-------+
¦ 325 ¦ 39 ¦ 77 ¦ 112 ¦ 149 ¦ 193 ¦ 233 ¦ 275 ¦ 319 ¦
¦ ¦ (34)¦ (66)¦ (96)¦ (128)¦ (166)¦ (200)¦ (237)¦ (274)¦
+--------+-----+------+-------+-------+-------+-------+-------+-------+
¦ 377 ¦ 44 ¦ 85 ¦ 124 ¦ 164 ¦ 212 ¦ 256 ¦ 301 ¦ 348 ¦
¦ ¦ (38)¦ (73)¦ (107)¦ (141)¦ (182)¦ (220)¦ (259)¦ (299)¦
+--------+-----+------+-------+-------+-------+-------+-------+-------+
¦ 426 ¦ 48 ¦ 93 ¦ 135 ¦ 178 ¦ 230 ¦ 276 ¦ 324 ¦ 374 ¦
¦ ¦ (41)¦ (80)¦ (116)¦ (153)¦ (198)¦ (237)¦ (279)¦ (322)¦
+--------+-----+------+-------+-------+-------+-------+-------+-------+
¦ 478 ¦ 52 ¦ 101 ¦ 145 ¦ 190 ¦ 245 ¦ 294 ¦ 345 ¦ 398 ¦
¦ ¦ (45)¦ (87)¦ (125)¦ (163)¦ (211)¦ (253)¦ (297)¦ (342)¦
+--------+-----+------+-------+-------+-------+-------+-------+-------+
¦ 529 ¦ 57 ¦ 109 ¦ 156 ¦ 205 ¦ 264 ¦ 316 ¦ 370 ¦ 426 ¦
¦ ¦ (49)¦ (94)¦ (134)¦ (176)¦ (227)¦ (272)¦ (318)¦ (366)¦
+--------+-----+------+-------+-------+-------+-------+-------+-------+
¦ 630 ¦ 67 ¦ 125 ¦ 179 ¦ 232 ¦ 298 ¦ 356 ¦ 415 ¦ 477 ¦
¦ ¦ (58)¦ (108)¦ (154)¦ (200)¦ (256)¦ (306)¦ (357)¦ (410)¦
+--------+-----+------+-------+-------+-------+-------+-------+-------+
¦ 720 ¦ 74 ¦ 139 ¦ 199 ¦ 256 ¦ 328 ¦ 391 ¦ 456 ¦ 522 ¦
¦ ¦ (64)¦ (120)¦ (171)¦ (220)¦ (282)¦ (336)¦ (392)¦ (448)¦
+--------+-----+------+-------+-------+-------+-------+-------+-------+
¦ 820 ¦ 84 ¦ 155 ¦ 220 ¦ 283 ¦ 362 ¦ 430 ¦ 499 ¦ 571 ¦
¦ ¦ (72)¦ (133)¦ (189)¦ (243)¦ (311)¦ (370)¦ (429)¦ (491)¦
+--------+-----+------+-------+-------+-------+-------+-------+-------+
¦ 920 ¦ 93 ¦ 170 ¦ 241 ¦ 309 ¦ 395 ¦ 468 ¦ 543 ¦ 620 ¦
¦ ¦ (80)¦ (146)¦ (207)¦ (266)¦ (340)¦ (402)¦ (467)¦ (533)¦
+--------+-----+------+-------+-------+-------+-------+-------+-------+
¦ 1020 ¦ 102 ¦ 186 ¦ 262 ¦ 335 ¦ 428 ¦ 506 ¦ 585 ¦ 668 ¦
¦ ¦ (88)¦ (160)¦ (225)¦ (288)¦ (368)¦ (435)¦ (504)¦ (574)¦
+--------+-----+------+-------+-------+-------+-------+-------+-------+
¦Криволи-¦ Нормы плотности теплового потока, Вт/кв.м (ккал/кв.м) ¦
¦нейные +-----+------+-------+-------+-------+-------+-------+-------+
¦поверх- ¦ 29 ¦ 50 ¦ 68 ¦ 83 ¦ 104 ¦ 119 ¦ 134 ¦ 149 ¦
¦ности ¦ (25)¦ (43)¦ (58)¦ (71)¦ (89)¦ (102)¦ (115)¦ (128)¦
¦диамет- ¦ ¦ ¦ ¦ ¦ ¦ ¦ ¦ ¦
¦ром бо- ¦ ¦ ¦ ¦ ¦ ¦ ¦ ¦ ¦
¦лее 1020¦ ¦ ¦ ¦ ¦ ¦ ¦ ¦ ¦
¦мм и ¦ ¦ ¦ ¦ ¦ ¦ ¦ ¦ ¦
¦плоские ¦ ¦ ¦ ¦ ¦ ¦ ¦ ¦ ¦
¦--------+-----+------+-------+-------+-------+-------+-------+--------
-------------------------------
Д - греческая буква "дельта"
т - греческая буква "тау"
Примечания:
1. Нормы плотности теплового потока определены из таблицы 1
приложения 4 СНиП 2.04.14-88 "Тепловая изоляция оборудования и
трубопроводов", утв. Постановлением Государственного строительного
комитета СССР от 19 августа 1988 г. N 155, изданы Госстроем СССР,
Москва, 1989 г., введены 1 января 1990 г.
2. Для участков тепловых сетей, сооруженных по проектам,
выполненным после 1 июля 1995 г., вводится коэффициент K = 0,8
Т1
(Изменение N 1 к СНиП 2.04.14-88, введенное постановлением
Государственного комитета Республики Беларусь по строительству и
архитектуре N 67 от 17 марта 1995 г.).
3. При расположении трубопроводов в тоннеле (проходном канале)
следует вводить коэффициент K = 0,85 (примечание 1 к таблице 3
т3
приложения 4 СНиП 2.04.14-88).
Приложение Р
(обязательное)
Таблица Р.1 - НОРМЫ ПЛОТНОСТИ ТЕПЛОВОГО ПОТОКА
ПРИ РАСПОЛОЖЕНИИ В ПОМЕЩЕНИИ (ТЕХНИЧЕСКОМ ПОДПОЛЬЕ)
И ТОННЕЛЕ (ПРОХОДНОМ КАНАЛЕ) ДЛЯ ТЕПЛОПРОВОДОВ СО СРОКОМ
ВВОДА В ЭКСПЛУАТАЦИЮ С 1994 Г. С ЧИСЛОМ ЧАСОВ
РАБОТЫ В ГОД 5000 И МЕНЕЕ
---------+-------------------------------------------------------------¬
¦Наружный¦ Удельная плотность теплового потока, q , Вт/м (ккал/м·ч) ¦
¦диаметр,¦ н ¦
¦ d, мм +-------------------------------------------------------------+
¦ ¦ Средняя разность температур теплоносителя и окружающего ¦
¦ ¦ трубопровод воздуха (помещение Дt = t - 15 / тоннель ¦
¦ ¦ пом ¦
¦ ¦ ¦
¦ ¦ Дt = t - 40, град. C) ¦
¦ ¦ т ¦
¦ +------+------+-------+-------+-------+-------+-------+-------+
¦ ¦35/10 ¦ 85/60¦135/110¦185/160¦235/210¦285/260¦335/310¦385/360¦
+--------+------+------+-------+-------+-------+-------+-------+-------+
¦ 21,3¦ 9 ¦ 20 ¦ 31 ¦ 44 ¦ 57 ¦ 72 ¦ 87 ¦ 104 ¦
¦ ¦ (7,7)¦ (17)¦ (27)¦ (38)¦ (49)¦ (62)¦ (75)¦ (89)¦
+--------+------+------+-------+-------+-------+-------+-------+-------+
¦ 26,8¦ 10 ¦ 22 ¦ 35 ¦ 49 ¦ 64 ¦ 80 ¦ 97 ¦ 115 ¦
¦ ¦ (8,6)¦ (19)¦ (30)¦ (42)¦ (55)¦ (69)¦ (83)¦ (99)¦
+--------+------+------+-------+-------+-------+-------+-------+-------+
¦ 32 ¦ 11 ¦ 25 ¦ 39 ¦ 54 ¦ 70 ¦ 87 ¦ 106 ¦ 125 ¦
¦ ¦ (9,5)¦(21,5)¦ (33,5)¦ (46)¦ (60)¦ (75)¦ (91)¦(107,5)¦
+--------+------+------+-------+-------+-------+-------+-------+-------+
¦ 22 ¦ 9 ¦ 20 ¦ 31 ¦ 44 ¦ 57 ¦ 72 ¦ 87 ¦ 104 ¦
¦ ¦ (8)¦ (17)¦ (27)¦ (38)¦ (49)¦ (62)¦ (75)¦ (89)¦
+--------+------+------+-------+-------+-------+-------+-------+-------+
¦ 27 ¦ 10 ¦ 22 ¦ 35 ¦ 49 ¦ 64 ¦ 80 ¦ 97 ¦ 115 ¦
¦ ¦ (8,6)¦ (19)¦ (30)¦ (42)¦ (55)¦ (69)¦ (83)¦ (99)¦
+--------+------+------+-------+-------+-------+-------+-------+-------+
¦ 32 ¦ 11 ¦ 25 ¦ 39 ¦ 54 ¦ 70 ¦ 87 ¦ 106 ¦ 125 ¦
¦ ¦ (9)¦(21,5)¦ (34)¦ (46)¦ (60)¦ (75)¦ (91)¦ (108)¦
+--------+------+------+-------+-------+-------+-------+-------+-------+
¦ 48 ¦ 13 ¦ 29 ¦ 46 ¦ 64 ¦ 83 ¦ 103 ¦ 124 ¦ 146 ¦
¦ ¦ (11)¦ (25)¦ (40)¦ (55)¦ (71)¦ (89)¦ (107)¦ (126)¦
+--------+------+------+-------+-------+-------+-------+-------+-------+
¦ 57 ¦ 15 ¦ 32 ¦ 49 ¦ 68 ¦ 89 ¦ 110 ¦ 132 ¦ 156 ¦
¦ ¦ (13)¦ (28)¦ (42)¦ (58)¦ (77)¦ (95)¦ (114)¦ (134)¦
+--------+------+------+-------+-------+-------+-------+-------+-------+
¦ 76 ¦ 17 ¦ 37 ¦ 57 ¦ 78 ¦ 101 ¦ 124 ¦ 149 ¦ 176 ¦
¦ ¦ (15)¦ (32)¦ (49)¦ (67)¦ (87)¦ (107)¦ (128)¦ (151)¦
+--------+------+------+-------+-------+-------+-------+-------+-------+
¦ 89 ¦ 20 ¦ 41 ¦ 62 ¦ 84 ¦ 108 ¦ 133 ¦ 160 ¦ 188 ¦
¦ ¦ (17)¦ (35)¦ (53)¦ (72)¦ (93)¦ (114)¦ (138)¦ (162)¦
+--------+------+------+-------+-------+-------+-------+-------+-------+
¦ 108 ¦ 22 ¦ 45 ¦ 69 ¦ 93 ¦ 119 ¦ 146 ¦ 175 ¦ 205 ¦
¦ ¦ (19)¦ (39)¦ (59)¦ (80)¦ (102)¦ (126)¦ (151)¦ (176)¦
+--------+------+------+-------+-------+-------+-------+-------+-------+
¦ 133 ¦ 25 ¦ 51 ¦ 77 ¦ 102 ¦ 135 ¦ 165 ¦ 196 ¦ 229 ¦
¦ ¦(21,5)¦ (44)¦ (66)¦ (88)¦ (116)¦ (142)¦ (169)¦ (197)¦
+--------+------+------+-------+-------+-------+-------+-------+-------+
¦ 159 ¦ 28 ¦ 56 ¦ 85 ¦ 114 ¦ 149 ¦ 181 ¦ 215 ¦ 251 ¦
¦ ¦ (24)¦ (48)¦ (73)¦ (98)¦ (128)¦ (156)¦ (185)¦ (216)¦
+--------+------+------+-------+-------+-------+-------+-------+-------+
¦ 219 ¦ 36 ¦ 70 ¦ 103 ¦ 137 ¦ 179 ¦ 216 ¦ 256 ¦ 299 ¦
¦ ¦ (31)¦ (60)¦ (89)¦ (118)¦ (154)¦ (186)¦ (220)¦ (257)¦
+--------+------+------+-------+-------+-------+-------+-------+-------+
¦ 273 ¦ 42 ¦ 81 ¦ 118 ¦ 155 ¦ 201 ¦ 242 ¦ 287 ¦ 332 ¦
¦ ¦ (36)¦ (70)¦ (101)¦ (133)¦ (173)¦ (208)¦ (247)¦ (286)¦
+--------+------+------+-------+-------+-------+-------+-------+-------+
¦ 325 ¦ 48 ¦ 92 ¦ 133 ¦ 174 ¦ 225 ¦ 270 ¦ 319 ¦ 368 ¦
¦ ¦ (41)¦ (79)¦ (114)¦ (150)¦ (194)¦ (232)¦ (274)¦ (316)¦
+--------+------+------+-------+-------+-------+-------+-------+-------+
¦ 377 ¦ 53 ¦ 103 ¦ 147 ¦ 193 ¦ 248 ¦ 299 ¦ 350 ¦ 404 ¦
¦ ¦ (46)¦ (89)¦ (126)¦ (166)¦ (213)¦ (257)¦ (301)¦ (347)¦
+--------+------+------+-------+-------+-------+-------+-------+-------+
¦ 426 ¦ 60 ¦ 113 ¦ 162 ¦ 210 ¦ 269 ¦ 324 ¦ 379 ¦ 436 ¦
¦ ¦ (52)¦ (97)¦ (139)¦ (181)¦ (231)¦ (279)¦ (326)¦ (375)¦
+--------+------+------+-------+-------+-------+-------+-------+-------+
¦ 478 ¦ 64 ¦ 122 ¦ 173 ¦ 225 ¦ 291 ¦ 347 ¦ 405 ¦ 465 ¦
¦ ¦ (55)¦ (105)¦ (149)¦ (194)¦ (250)¦ (298)¦ (348)¦ (400)¦
+--------+------+------+-------+-------+-------+-------+-------+-------+
¦ 529 ¦ 71 ¦ 132 ¦ 188 ¦ 243 ¦ 314 ¦ 373 ¦ 435 ¦ 499 ¦
¦ ¦ (61)¦ (114)¦ (162)¦ (209)¦ (270)¦ (321)¦ (374)¦ (429)¦
+--------+------+------+-------+-------+-------+-------+-------+-------+
¦ 630 ¦ 81 ¦ 152 ¦ 215 ¦ 277 ¦ 357 ¦ 423 ¦ 492 ¦ 562 ¦
¦ ¦ (70)¦ (131)¦ (185)¦ (238)¦ (307)¦ (364)¦ (423)¦ (483)¦
+--------+------+------+-------+-------+-------+-------+-------+-------+
¦ 720 ¦ 91 ¦ 170 ¦ 239 ¦ 309 ¦ 394 ¦ 467 ¦ 541 ¦ 618 ¦
¦ ¦ (78)¦ (146)¦ (206)¦ (266)¦ (339)¦ (406)¦ (465)¦ (531)¦
+--------+------+------+-------+-------+-------+-------+-------+-------+
¦ 820 ¦ 102 ¦ 190 ¦ 265 ¦ 342 ¦ 436 ¦ 515 ¦ 596 ¦ 679 ¦
¦ ¦ (88)¦ (163)¦ (228)¦ (294)¦ (375)¦ (443)¦ (513)¦ (584)¦
+--------+------+------+-------+-------+-------+-------+-------+-------+
¦ 920 ¦ 114 ¦ 209 ¦ 292 ¦ 375 ¦ 478 ¦ 563 ¦ 650 ¦ 740 ¦
¦ ¦ (98)¦ (180)¦ (251)¦ (323)¦ (411)¦ (484)¦ (559)¦ (636)¦
+--------+------+------+-------+-------+-------+-------+-------+-------+
¦ 1020 ¦ 125 ¦ 229 ¦ 318 ¦ 408 ¦ 519 ¦ 611 ¦ 704 ¦ 800 ¦
¦ ¦ (108)¦ (197)¦ (273)¦ (351)¦ (446)¦ (525)¦ (605)¦ (688)¦
+--------+------+------+-------+-------+-------+-------+-------+-------+
¦Криволи-¦ Нормы плотности теплового потока, Вт/кв.м (ккал/кв.м) ¦
¦нейные +------+------+-------+-------+-------+-------+-------+-------+
¦поверх- ¦ 36 ¦ 63 ¦ 85 ¦ 105 ¦ 132 ¦ 151 ¦ 170 ¦ 188 ¦
¦ности ¦ (25)¦ (43)¦ (58)¦ (71)¦ (89)¦ (102)¦ (115)¦ (128)¦
¦диамет- ¦ ¦ ¦ ¦ ¦ ¦ ¦ ¦ ¦
¦ром бо- ¦ ¦ ¦ ¦ ¦ ¦ ¦ ¦ ¦
¦лее 1020¦ ¦ ¦ ¦ ¦ ¦ ¦ ¦ ¦
¦мм и ¦ ¦ ¦ ¦ ¦ ¦ ¦ ¦ ¦
¦плоские ¦ ¦ ¦ ¦ ¦ ¦ ¦ ¦ ¦
¦--------+------+------+-------+-------+-------+-------+-------+--------
-------------------------------
Д - греческая буква "дельта"
т - греческая буква "тау"
Примечания:
1. Нормы плотности теплового потока определены из таблицы 1
приложения 4 СНиП 2.04.14-88 "Тепловая изоляция оборудования и
трубопроводов", утв. Постановлением Государственного строительного
комитета СССР от 19 августа 1988 г. N 155, изданы Госстроем СССР,
Москва, 1989 г., введены 1 января 1990 г.
2. Для участков тепловых сетей, сооруженных по проектам,
выполненным после 1 июля 1995 г., вводится коэффициент K = 0,8
Т1
(Изменение N 1 к СНиП 2.04.14-88, введенное постановлением
Государственного комитета Республики Беларусь по строительству и
архитектуре N 67 от 17 марта 1995 г.).
3. При расположении трубопроводов в тоннеле (проходном канале)
следует вводить коэффициент K = 0,85 (примечание 1 к таблице 3
Т3
приложения 4 СНиП 2.04.14-88).
Приложение С
(справочное)
Таблица С.1 - ПЛОЩАДЬ ПОПЕРЕЧНОГО СЕЧЕНИЯ
ТРУБОПРОВОДА "В СВЕТУ"
--------------+-------+-----------+-------------+-------+-----------¬
¦ Наружный ¦Толщина¦ Площадь ¦ Наружный ¦Толщина¦ Площадь ¦
¦ диаметр ¦стенки,¦поперечного¦ диаметр ¦стенки,¦поперечного¦
¦трубопровода,¦ д, мм ¦сечения, f,¦трубопровода,¦ д, мм ¦сечения, f,¦
¦ d, мм ¦ ¦ кв.м ¦ d, мм ¦ ¦ кв.м ¦
+-------------+-------+-----------+-------------+-------+-----------+
¦ 48¦ 2,5¦ 0,001451¦ 426¦ 8,0¦ 0,1320¦
+-------------+-------+-----------+-------------+-------+-----------+
¦ 48¦ 3,5¦ 0,00132¦ 426¦ 9,0¦ 0,1307¦
+-------------+-------+-----------+-------------+-------+-----------+
¦ 57¦ 3,5¦ 0,001963¦ 426¦ 10,0¦ 0,1294¦
+-------------+-------+-----------+-------------+-------+-----------+
¦ 76¦ 3,5¦ 0,003737¦ 478¦ 8,0¦ 0,1676¦
+-------------+-------+-----------+-------------+-------+-----------+
¦ 89¦ 3,5¦ 0,005278¦ 478¦ 9,0¦ 0,1661¦
+-------------+-------+-----------+-------------+-------+-----------+
¦ 89¦ 4,0¦ 0,00515¦ 478¦ 10,0¦ 0,1647¦
+-------------+-------+-----------+-------------+-------+-----------+
¦ 108¦ 4,0¦ 0,00785¦ 529¦ 8,0¦ 0,2066¦
+-------------+-------+-----------+-------------+-------+-----------+
¦ 133¦ 4,0¦ 0,01227¦ 529¦ 9,0¦ 0,2050¦
+-------------+-------+-----------+-------------+-------+-----------+
¦ 159¦ 4,5¦ 0,01766¦ 529¦ 10,0¦ 0,2034¦
+-------------+-------+-----------+-------------+-------+-----------+
¦ 219¦ 6,0¦ 0,03364¦ 630¦ 8,0¦ 0,2959¦
+-------------+-------+-----------+-------------+-------+-----------+
¦ 219¦ 8,0¦ 0,03235¦ 630¦ 9,0¦ 0,2940¦
+-------------+-------+-----------+-------------+-------+-----------+
¦ 273¦ 7,0¦ 0,05266¦ 720¦ 10,0¦ 0,3847¦
+-------------+-------+-----------+-------------+-------+-----------+
¦ 273¦ 8,0¦ 0,05185¦ 820¦ 12,0¦ 0,4974¦
+-------------+-------+-----------+-------------+-------+-----------+
¦ 273¦ 9,0¦ 0,05104¦ 920¦ 12,0¦ 0,6302¦
+-------------+-------+-----------+-------------+-------+-----------+
¦ 325¦ 8,0¦ 0,07496¦ 920¦ 13,0¦ 0,6274¦
+-------------+-------+-----------+-------------+-------+-----------+
¦ 325¦ 9,0¦ 0,07399¦ 1020¦ 11,0¦ 0,7819¦
+-------------+-------+-----------+-------------+-------+-----------+
¦ 325¦ 10,0¦ 0,07302¦ 1020¦ 13,0¦ 0,7756¦
+-------------+-------+-----------+-------------+-------+-----------+
¦ 377¦ 10,0¦ 0,10005¦ 1220¦ 12,0¦ 1,1229¦
+-------------+-------+-----------+-------------+-------+-----------+
¦ 377¦ 9,0¦ 0,10117¦ 1420¦ 14,0¦ 1,5211¦
+-------------+-------+-----------+-------------+-------+-----------+
¦ 377¦ 8,0¦ 0,10230¦ 1420¦ 13,0¦ 1,5254¦
¦-------------+-------+-----------+-------------+-------+------------
Примечание. Площадь поперечного сечения "в свету" определялась
-7 2
по формуле f = 7,85 · 10 · (d - 2д) , кв.м.
Приложение Т
(обязательное)
Приложение Т.1 - УДЕЛЬНЫЙ ОБЪЕМ ВОДЫ В СИСТЕМАХ
ТЕПЛОПОТРЕБЛЕНИЯ ПРИ РАЗЛИЧНЫХ ПЕРЕПАДАХ ТЕМПЕРАТУР
В ЗАВИСИМОСТИ ОТ ТИПА ТЕПЛОПОТРЕБЛЯЮЩИХ СИСТЕМ
----+------------------+----------------------------------------------------¬
¦ N ¦ Теплопотребляющее¦ Удельный объем воды w , куб.м/МВт (куб.мч/Гкал) при¦
¦п/п¦ оборудование ¦ i ¦
¦ ¦ в системе ¦ температурном перепаде в системе град. C ¦
¦ ¦ +-------+--------+--------+--------+--------+--------+
¦ ¦ ¦95 - 70¦110 - 70¦130 - 70¦140 - 70¦150 - 70¦180 - 70¦
+---+------------------+-------+--------+--------+--------+--------+--------+
¦ 1 ¦Радиаторы чугунные¦ 26,7 ¦ 24,3 ¦ 20,8 ¦ 20,0 ¦ 18,6 ¦ 15,7 ¦
¦ ¦высотой 1000 мм ¦ (31,0)¦ (28,2)¦ (24,2)¦ (23,2)¦ (21,6)¦ (18,2)¦
+---+------------------+-------+--------+--------+--------+--------+--------+
¦ 2 ¦Радиаторы чугунные¦ 16,8 ¦ 15,1 ¦ 13,0 ¦ 12,6 ¦ 11,4 ¦ 9,5 ¦
¦ ¦высотой 500 мм ¦ (19,5)¦ (17,6)¦ (15,1)¦ (14,6)¦ (13,3)¦ (11,1)¦
+---+------------------+-------+--------+--------+--------+--------+--------+
¦ 3 ¦Радиаторы стальные¦ 10,1 ¦ 9,1 ¦ 7,8 ¦ 7,6 ¦ 6,9 ¦ 5,8 ¦
¦ ¦панельные высотой ¦ (11,7)¦ (10,6)¦ (9,1)¦ (8,8)¦ (8,0)¦ (6,7)¦
¦ ¦500 мм ¦ ¦ ¦ ¦ ¦ ¦ ¦
+---+------------------+-------+--------+--------+--------+--------+--------+
¦ 4 ¦Радиаторы стальные¦ 8,6 ¦ 7,7 ¦ 6,7 ¦ 6,45¦ 5,8 ¦ 4,8 ¦
¦ ¦панельные высотой ¦ (10,0)¦ (9,0)¦ (7,8)¦ (7,5)¦ (6,8)¦ (5,6)¦
¦ ¦350 мм ¦ ¦ ¦ ¦ ¦ ¦ ¦
+---+------------------+-------+--------+--------+--------+--------+--------+
¦ 5 ¦Радиаторы стальные¦ 4,8 ¦ 4,3 ¦ 3,7 ¦ 3,5 ¦ 3,2 ¦ 2,8 ¦
¦ ¦листотрубные и ¦ (5,6)¦ (5,0)¦ (4,3)¦ (4,1)¦ (3,7)¦ (3,2)¦
¦ ¦конвекторы ¦ ¦ ¦ ¦ ¦ ¦ ¦
+---+------------------+-------+--------+--------+--------+--------+--------+
¦ 6 ¦Трубы чугунные ¦ 12,2 ¦ 10,8 ¦ 9,3 ¦ 8,9 ¦ 7,9 ¦ 6,9 ¦
¦ ¦ребристые ¦ (14,2)¦ (12,5)¦ (10,8)¦ (10,4)¦ (9,2)¦ (8,0)¦
+---+------------------+-------+--------+--------+--------+--------+--------+
¦ 7 ¦Регистры ¦ 31,8 ¦ 27,5 ¦ 23,2 ¦ 22,4 ¦ 20,6 ¦ 18,9 ¦
¦ ¦из стальных труб ¦ (37,0)¦ (32,0)¦ (27,0)¦ (26,0)¦ (24,0)¦ (22,0)¦
¦ ¦ ¦ ¦ ¦ ¦ ¦ ¦ ¦
+---+------------------+-------+--------+--------+--------+--------+--------+
¦ 8 ¦Калориферные ото- ¦ 7,3 ¦ 6,45¦ 5,6 ¦ 5,2 ¦ 4,7 ¦ 3,8 ¦
¦ ¦пительно-вентиля- ¦ (8,5)¦ (7,5)¦ (6,5)¦ (6,0)¦ (5,5)¦ (4,4)¦
¦ ¦ционные агрегаты ¦ ¦ ¦ ¦ ¦ ¦ ¦
¦---+------------------+-------+--------+--------+--------+--------+---------
-------------------------------
w - греческая буква "ни"
Примечание. Удельный объем воды в системах теплопотребления определен из приложения 2 "Методических указаний по составлению энергетических характеристик для систем транспорта тепловой энергии (в трех частях). РД 153-34.0-20.523-98. Часть III. Методические указания по составлению энергетической характеристики по показателю "потери сетевой воды", утв. Департаментом стратегии развития и научно-технической политики РАО "ЕАС России" 6 июля 1998 г., издано СПО ОРГРЭС, Москва, 1999 г.
Приложение У
(обязательное)
Таблица У.1 - НОРМЫ УДЕЛЬНЫХ ПОТЕРЬ ТЕПЛА ИЗОЛИРОВАННЫМИ
ТРУБОПРОВОДАМИ ГОРЯЧЕГО ВОДОСНАБЖЕНИЯ И ЦИРКУЛЯЦИОННЫМИ
ПРИ ПРОКЛАДКЕ В НЕПРОХОДНЫХ КАНАЛАХ,
СООРУЖЕННЫМИ ДО 1994 ГОДА
Вт/м (ккал/м·ч)
-------------------+-----------------------------------------------¬
¦ Наружный диаметр ¦ Удельные потери тепла при разности температур ¦
¦ трубопровода, мм ¦ теплоносителя (t ) и грунта (т = 5 град. C):¦
¦ ¦ т гр ¦
¦ ¦ ¦
¦ ¦ Дt = t - 5, град. C ¦
¦ ¦ т ¦
¦ +-----------------------+-----------------------+
¦ ¦ 45 ¦ 65 ¦
¦ +----------+------------+----------+------------+
¦ ¦q , Вт/м·K¦q , Ккал/м·ч¦q , Вт/м·K¦q , Ккал/м·ч¦
¦ ¦ н ¦ н ¦ н ¦ н ¦
+------------------+----------+------------+----------+------------+
¦ 32 ¦ 17¦ 15 ¦ 24¦ 21¦
+------------------+----------+------------+----------+------------+
¦ 38 ¦ 19¦ 16,5¦ 27¦ 23¦
+------------------+----------+------------+----------+------------+
¦ 45 ¦ 21¦ 18 ¦ 29¦ 25¦
+------------------+----------+------------+----------+------------+
¦ 57 ¦ 24¦ 21 ¦ 33¦ 28¦
+------------------+----------+------------+----------+------------+
¦ 76 ¦ 29¦ 25 ¦ 38¦ 33¦
+------------------+----------+------------+----------+------------+
¦ 89 ¦ 33¦ 28 ¦ 42¦ 36¦
+------------------+----------+------------+----------+------------+
¦ 108 ¦ 36¦ 31 ¦ 47¦ 40¦
+------------------+----------+------------+----------+------------+
¦ 133 ¦ 41¦ 35 ¦ 52¦ 45¦
Страницы: | Стр.1 | Стр.2 | Стр.3 | Стр.4 | Стр.5 | Стр.6 | Стр.7 | Стр.8 | Стр.9 | Стр.10 | Стр.11 | Стр.12 | Стр.13 | Стр.14 | Стр.15 | Стр.16 | Стр.17 | Стр.18 | Стр.19 |
|